Title Calibration of the NEXT-White detector using 83m Kr decays
Abstract

The NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. It has been operating at Laboratorio Subterr'aneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed using 83m Kr decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event transverse position which is caused by variations in solid angle coverage both for direct and reflected light and edge effects. After producing calibration maps to correct for both effects we measure an excellent energy resolution for 41.5 keV point-like deposits of (4.553 ± 0.010 (stat) ± 0.324 (sys))% FWHM in the full chamber and (3.804 ± 0.013 (stat) ± 0.112 (sys))% FWHM in a restricted fiducial volume. Using naive 1/√ E scaling, these values translate into resolutions of (0.5916 ± 0.0014 (stat) ± 0.0421 (sys))% FWHM and (0.4943 ± 0.0017 (stat) ± 0.0146 (sys))% FWHM at the Q ββ energy of xenon double beta decay (2458 keV), well within range of our target value of 1%.

Apa Reference Martínez-Lema, G., Morata, J.H., Palmeiro, B., Botas, A., Ferrario, P., Monrabal, F., Laing, A., Renner, J., Simón, A., Para, A., Gómez-Cadenas, J., Adams, C., Álvarez, V., Arazi, L., Azevedo, C., Bailey, K., Ballester, F., Benlloch-Rodríguez, J., Borges, F., Cárcel, S., Carrión, J., Cebrián, S., Conde, C., Díaz, J., Diesburg, M., Escada, J., Esteve, R., Felkai, R., Fernandes, A., Fernandes, L., Ferreira, A., Freitas, E., Generowicz, J., Goldschmidt, A., González-Díaz, D., Guenette, R., Gutiérrez, R., Hafidi, K., Hauptman, J., Henriques, C., Hernandez, A., Herrero, V., Johnston, S., Jones, B., Kekic, M., Labarga, L., Lebrun, P., López-March, N., Losada, M., Mano, R., Martín-Albo, J., Martínez, A., McDonald, A., Monteiro, C., Mora, F., Vidal, J.M., Musti, M., Nebot-Guinot, M., Novella, P., Nygren, D., Pérez, J., Querol, M., Repond, J., Riordan, S., Ripoll, L., Rodríguez, J., Rogers, L., Romo-Luque, C., Santos, F., Santos, J.d., Sofka, C., Sorel, M., Stiegler, T., Toledo, J., Torrent, J., Veloso, J., Webb, R., White, J. & Yahlali, N. (2018). Calibration of the NEXT-White detector using 83m Kr decays. Journal of Instrumentation, 13(10), P10014-P10014. 10.1088/1748-0221/13/10/P10014
Doi 10.1088/1748-0221/13/10/P10014
Publication Date 10 Oct 2018
Publication Type Article
Researcher José Vicente Carrión Burguete
Ontology
Research Groups
Tools

Suggest changes

Publications are synced automatically from ORCID, so they can't be edited here directly. Spotted something wrong? Let us know below and we'll take care of it.

← Return to Home